CREA: Colección de Recursos Educativos Abiertos

 

Análisis de las medidas de refuerzo y reacondicionamiento sísmico en las estructuras de edificios dañados por los terremotos de Lorca

dc.audience.mediatorUniversidad de Jaén. Escuela Politécnica Superior (Linares)es_ES
dc.contributor.advisorDonaire Ávila, Jesúses_ES
dc.contributor.authorEspadas Priego, Álvaroes_ES
dc.contributor.otherUniversidad de Jaén. Ingeniería Mecánica y Mineraes_ES
dc.date.accessioned2017-09-26T07:56:35Z
dc.date.available2017-09-26T07:56:35Z
dc.date.issued2017-09-26
dc.description.abstractLos terremotos de Lorca de mayo de 2011, catalogados como impulsivos cerca de falla, produjeron diferentes daños en la estructura de los edificios, sobre todo en planta baja. En este TFG se estudia una estructura de un edificio de 4 plantas, formada por pórticos de hormigón armado con vigas planas. Se analiza la carga sísmica, debido tanto a la acción de proyecto como a la real del terremoto de Lorca. Se determinan tanto las acciones en pilares de planta baja como los desplazamientos de la estructura para obtener su nivel de ductilidad. A partir de los resultados obtenidos en los cálculos se plantea como medida de reacondicionamiento el recrecido de hormigón armado en pilares de planta baja con el objetivo de mejorar resistencia y ductilidad. Finalmente se lleva a cabo el análisis de la estructura reacondicionada, comparando los resultados antes y después de aplicar el refuerzo, dictaminando su bondad respecto a la demanda de resistencia y desplazamiento a la que se ve sometida la estructura.es_ES
dc.description.abstractThe Lorca earthquakes of May of 2011 (pulse-like ground motions) led to different damages for the structure of the buildings, mainly in ground floor. This TFG is based on the 4-story reinforced concrete building with shallow beams. A seismic analysis is carried out taking into account both the project and the real seismic action from the Lorca earthquakes. Forces are determined for columns of the ground floor as well as the displacements of the structure to obtain the story ductility level. Once the results are obtained from the calculations, the reinforced concrete jacketed is put forward as a measure to retrofit the columns of the structure on ground floor to improve both the strength and the ductility. Finally, the analysis of the retrofitted structure is carried out, comparing the results before and after applying the strenthening. The goodness of the retrofitted structure is discussed in terms of strength and ductility.en
dc.identifier.urihttp://hdl.handle.net/10953.1/5110
dc.language.isospaes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subject.classification3305.26es_ES
dc.subject.classification3305.33es_ES
dc.subject.otherEdificios públicoses_ES
dc.subject.otherResistencia de estructurases_ES
dc.titleAnálisis de las medidas de refuerzo y reacondicionamiento sísmico en las estructuras de edificios dañados por los terremotos de Lorcaes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
TFG.AlvaroEspadasPriego.pdf
Tamaño:
4.41 MB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.96 KB
Formato:
Item-specific license agreed upon to submission
Descripción: